Why Choose a Quality Wastewater Treatment System from Delta

Whitewater Series – DF and UC Models of Wastewater Aerobic Treatment Units

ECOPOD Series: Residential Wastewater Treatment System

ECOPOD-N

ECOPOD-D

ECOPOD-C

Aerobic Wastewater Treatment Unit Combinations Controls

Air Compressors

Alarms and Control Panels


DF SERIES UNIT
The Clear Choice for Wastewater On-Site Disposal System is the WhitewaterŽ Aerobic Treatment Unit (ATU). The WhitewaterŽ ATU was tested under standard 40 of ANSI/NSF International and met and exceeded Class I requirements with an average effluent quality of 6 mg/L BOD5 and 7 mg/L TSS.
  • Why use a WhitewaterŽ Aerobic Treatment Unit ?
  • ANSI/NSF International Standard 40 Class 1 Certified
  • Disposes of wastewater quietly, efficiently and with no odor
  • DF40 & DF50 operates on same power as a light bulb
  • FHA and VA acceptable
  • Low initial capital cost & operation
  • No inner tank filters, screens or diffusers to service
  • Enhances any on-site disposal system
  • For use in adequate soils, smaller lots, high water tables,
    recreational areas or other difficult sites
  • Unit provides 90% reduction of viruses; 99% reduction of
    viruses with disinfection
  • Nitrates less than 10 MG/L with proper operation
  • 5/10 year limited warranty
Technical Data
Model GPD Diameter Height Electrical Inlet/Outlet
DF40 400 5.5' 5' 115v 4"
DF50 500 6' 5' 115v 4"
DF60 600 6'3" 5'9" 115v 4"
DF75 750 6'9" 6'2" 115v 4"
DF100A 1000 8' 6' 115v 4"
DF150 1500 8' 8'6" 115v 4"
UC SERIES UNIT
UltraClear Series The Clear Choice for Wastewater On-Site Disposal is the WhitewaterŽ UC Series Aerobic Treatment Unit (ATU). The WhitewaterŽ UC Series ATU was tested under standard 40 of ANSI/NSF International and met and exceeded Class I requirements with an average effluent quality of 6 mg/L BOD5 and 8 mg/L TSS.
  • Why use a WhitewaterŽ UC Series Aerobic Treatment Unit ?
  • ANSI/NSF International Standard 40 Class 1 Certified
  • Disposes of wastewater quietly, efficiently and with no odor
  • UC50 operates on same power as a light bulb
  • FHA and VA acceptable
  • State approved and accepted by sanitarians
  • Low initial capital cost & operation
  • No inner tank filters, screens or diffusers to service
  • For use where conventional septics are inadequate
  • Unit provides 90% reduction of viruses; 99% reduction of
    viruses with disinfection
  • 5/10 year limited warranty
Technical Data
Model GPD Diameter Height Electrical Inlet/Outlet
UC50 500 5'6" 5' 115v 4"
UC60 600 6'3" 5'9" 115v 4"
UC75 750 6'9" 6'2" 115v 4"
UC90 900 6'9" 6' 115v 4"
UC100A 1000 8' 6' 115v 4"
UC120 1200 7'8" 6'6" 115v 4"
UC150 1500 8' 8'6"